DM SUP 000:
• Power supply: 230V~ 50Hz
• Wall mounting
• Time, luminosity level and sensibility are adjustables
• Coverage:
- Max. angle: 180º
- Max. distance: 12m
• Load: 3000W Incandescent, 3000W Halogen 230V~, 2400W VLT Halogen, 1300W Fluorescent (130µF) and Compact Fluorescent lamps
• Admits contactor
|
|
| |
|
|
DM SUP 002:
• Power supply: 230V~ 50Hz
• Wall or ceiling mounting
• Time, luminosity level and sensibility are adjustables
• Coverage: 270º in 12m (max.)
• Load: 3000W Incandescent, 3000W Halogen 230V~, 2400W VLT Halogen, 1300W Fluorescent (130µF) and Compact Fluorescent lamps
• Admits contactor |
|
| |
|
|
|
DM BRA 001:
• Power supply: 230V~ 50Hz
• Wall or ceiling mounting
• Time, luminosity level and sensibility are adjustables
• Coverage: 200º in 12m (max.) at 2m high
• Load: 1000W Incandescent, 1000W Halogen 230V~, 800W VLT Halogen and 500W Fluorescent lamps (uncompensated)
• Admits contactor |
|
| |
|
|
|
DM TEC 001:
• Power supply: 230V~ 50Hz
• Ceiling mounting
• Time, luminosity level and sensibility are adjustables
• Coverage: 360º in Ø6m (max.) at 2.4m high
• Load: 1000W Incandescent, 1000W Halogen 230V~, 800W VLT Halogen and 500W Fluorescent lamps (uncompensated)
• Admits contactor |
|
| |
|
|
|
DM TEC 002:
• Power supply: 230V~ 50Hz
• Flush ceiling mounting
• Time, luminosity level and sensibility are adjustables
• Coverage: 360º in Ø6m (max.) at 2.4m high
• Load: 3000W Incandescent, 3000W Halogen 230V~, 2400W VLT Halogen, 1300W Fluorescent (130μF) and Compact Fluorescent lamps
• Admits contactor
• 2 output channels
• Admits until 9 extra sensors (DM SEN T01) |
|
| |
|
|
|
DM TEC 003:
• Power supply: 230V~ 50Hz
• Flush ceiling mounting
• Time, luminosity level and sensibility are adjustables
• Coverage: 360º in Ø6m (max.) at 2.4m high
• Load: 3000W Incandescent, 3000W Halogen 230V~, 2400W VLT Halogen, 1300W Fluorescent (130μF) and Compact Fluorescent lamps
• Admits contactor
• 1 output channel
• Not admits extra sensors |
|
| |
|
|
|
DM SEN T01:
• Flush ceiling mounting, together with DM TEC 002
• Luminosity level and sensibility are adjustables
• Coverage: 360º in Ø6m (max.) at 2.4m high |
|
| |
|
|
|
DM CAM 001:
• Power supply: 230V~ 50Hz
• Installation in universal box
• Time, luminosity level and sensibility are adjustables
• Coverage: 200º in 8m (max.) at 1.2 - 1.5m high
• Load: 2000W Incandescent, 1200W Halogen 230V~, 1000W VLT Halogen, 900W Fluorescent (100μF) and Compact Fluorescent lamps
• Admits contactor
• 3 wire installation |
|
| |
|
|
|
DM CAM 002:
• Power supply: 230V~ 50Hz
• Installation in universal box
• Time, luminosity level and sensibility are adjustables
• Coverage: 200º in 8m (max.) at 1.2 - 1.5m high
• Load: 400W Incandescent, 300W Halogen 230V~ and 300W VLT Halogen (trailing edge transformer)
• 2 wire installation |
|